January 19, 2021

Distinctive Notes
one. The power unit is of S3 duty, which could only be worked intermittently,i.e. 1minute on and 9 minutes off.
two. Clean every one of the hydraulic elements concerned ahead of set up of the electrical power unit.
three. Viscosity of the hydraulic oil shoud be 15~46 cst, which should really also be clean and free of charge of impurities, N46 hydraulic oil is advisable .
4. Check the oil level during the tank just after the preliminary operation with the electrical power unit.
5. Oil altering is needed after the original one hundred operation hours, afterwards when each and every 3000 hours.

Electrical power UNITS FOR DOCK LEVELER 4
Standard Description
This power unit is deigned for all those dock levellers which need floating ramps with an emergency quit function. The ramp will rise once the pump is running.The lip will expend instantly when the ramp cylinder finishes its stroke. The ramp cylinder will retract once the pump stops working. An emergency end might be realized although the solenoid valve is energized. The reducing pace of the two the ramp and also the lip is adjusted by the needle valves from the process.